Cleanroom LED panels are sealed, easy-to-wipe flat panels made for controlled environments such as labs, pharmaceutical and medical device production, electronics assembly, hospital support areas and food processing. Compared with a standard flat panel, they add sealed construction, a smooth cleanable face and an ingress rating. Always confirm the room's own requirements first.
Where are cleanroom LED panels used?
In general, they go wherever dust, particles or washdown are a concern. Technilight lists dust-free factories, laboratories, hospitals and pharmaceutical plants as typical uses for its cleanroom panels. Other common places, as general application knowledge, include:
- Laboratories and research rooms.
- Pharmaceutical and medical device production.
- Electronics assembly, where dust control matters.
- Hospital support areas, such as sterile processing and operating support spaces.
- Food processing rooms that are cleaned often.
For ordinary clinics and offices, a standard panel is usually enough. See our clinic and dental office lighting guide.
What makes a panel a cleanroom panel?
Technilight's spec sheet for its cleanroom panels lists fully welded construction, an antibacterial coating, a frosted polycarbonate lens and an aluminum body. It also states that the panels are Fraunhofer IPA certified for cleanrooms and compliant with cleanrooms of ISO cleanliness classes 3 to 9. The panels are also rated IP65 / IK03.
Whether a given room accepts a fixture depends on its cleanliness class and the owner's validation rules. Check those requirements with the facility or the design engineer before you order.
What does IP65 mean for a cleanroom fixture?
The first digit, 6, means the fixture is dust-tight. The second digit, 5, means it resists low-pressure water jets. IK03 is a separate impact rating and is a low one, so protect panels from knocks. Our IP ratings guide explains the full scale.
The product data lists IP65 / IK03 only. It does not describe a gasket or sealing method, so confirm sealing details with us or Technilight if your room needs them.
Do cleanroom panels fit a T-bar or gel-seal ceiling?
The product data says the panels use concealed front mounting brackets. It does not say they are compatible with a specific T-bar or gel-seal grid. Each panel is 3.94 in (100 mm) deep, so confirm fit and sealing with the ceiling system supplier before you order. Do not assume a standard drop-ceiling fit.
How do cleanroom panels differ from standard flat panels?
| Feature |
Technilight cleanroom panel |
Standard flat panel |
| Ingress rating |
IP65 / IK03 |
Check each product; often unrated |
| Construction |
Fully welded, antibacterial coating |
Varies by model |
| Wattage |
Selectable, 25-100W by size |
Varies; many are selectable |
| Colour temperature |
Selectable 3500 / 4000 / 5000K |
Varies by model |
| Best for |
Labs, pharma, food, dust-free areas |
Offices, schools, retail |
For standard rooms, see flat panel vs troffer and our LED panels and troffers. Cleanroom panels are not CRI 90 panels: their spec sheet lists CRI above 80.
Which Technilight cleanroom panel sizes and wattages are available?
| Size |
Model |
Selectable wattage |
Max. output |
| 1x4 |
TLCPUS14W40AD |
25 / 30 / 40W |
5,000 lm |
| 1x4 |
TLCPUS14W60AD |
40 / 48 / 60W |
7,500 lm |
| 2x2 |
TLCPUS22W40AD |
25 / 30 / 40W |
5,000 lm |
| 2x2 |
TLCPUS22W60AD |
40 / 48 / 60W |
7,500 lm |
| 2x4 |
TLCPUS24W50AD |
30 / 40 / 50W |
6,250 lm |
| 2x4 |
TLCPUS24W100AD |
60 / 80 / 100W |
12,500 lm |
All six accept 100-347V, are 0-10V dimmable and have a 110° beam. Colour temperature is selectable at 3500, 4000 or 5000K, and power is set before installation. Browse them all in the LED cleanroom panels collection.
How do you choose wattage and colour temperature?
- Pick the size that matches the layout: 1x4, 2x2 or 2x4.
- Run a photometric layout for the room, then choose the wattage setting that meets the target light level.
- Choose colour temperature by task. Cooler 5000K suits inspection-style work; 3500-4000K is more neutral. This is general guidance.
- Confirm the controls. These panels take a 0-10V dimming signal.
LitesGo prepares free DIALux/AGi32 photometric layouts for Technilight fixtures. Learn how the layout service works.
What should you check before ordering?
- The room's cleanliness class and any validation or sanitation rules.
- Ceiling system, depth and sealing method.
- Voltage on site, and the dimming control.
- Operating range: the spec sheet lists -25°C to 40°C.
- Local code. Check the Canadian Electrical Code and your local authority having jurisdiction (inspector).
Frequently asked questions
Are Technilight cleanroom panels IP65 rated?
Yes. The product data lists IP65 / IK03 for all six models.
Can the wattage and colour temperature be changed?
Yes. Power and colour temperature (3500, 4000 or 5000K) are selectable. Set them before installation.
Are cleanroom panels dimmable?
Yes. They are 0-10V dimmable and accept 100-347V input.
Do they fit a standard T-bar ceiling?
The product data does not state T-bar or gel-seal compatibility. Confirm fit with the ceiling system supplier.
Does LitesGo help with the lighting layout?
Yes. We prepare free DIALux/AGi32 photometric layouts for Technilight fixtures, and Technilight is exclusive to LitesGo in Western Canada.
Need pricing or a layout for a cleanroom project? Contact the LitesGo team or call (587) 701-5969. We are at 4914 89 St NW, Edmonton, AB T6E 5K1. Technilight items may be special order, so ask us to confirm availability and lead time. In-stock items usually dispatch in 1-2 business days anywhere in Canada.